ANRITSU MA2472D REPAIR and ANRITSU MA2472D CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANRITSU MA2472D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MA2472D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   ANRITSU MA2472D   Description / Specification:    
ANRITSU MA2472D 18 GHz Standard Diode Sensor

The Anritsu MA2472D 18 GHz Standard Diode Sensor is designed for use with the ML2430, ML2480 and ML2490 series power meters. They are designed for high dynamic range, high accuracy CW and TDMA measurements. These power sensors have 90 dB dynamic range and linearity better than 1.8% making them the choice for precision measurements. The 4 µs rise time of these sensors is fast enough for power measurements on GSM and similar TDMA systems that use GMSK modulation. Specifications. Frequency Range: 10 MHz to 18 GHz. Dynamic Range: –70 dBm to +20 dBm. SWR: <1.17; 10 MHz to 50 MHz, <1.17; 50 MHz to 150 MHz, <1.12; 150 MHz to 2 GHz, <1.22; 2 GHz to 12.4 GHz, <1.25; 12.4 GHz to 18 GHz. Rise Time (the time interval necessary for the power sensor to rise from 10% to 90% of the reading when the signal rises instantaneously from zero (no power) to 1 mW (0 dBm) at room temperature): <0.004 ms. Sensor Linearity –70 to +20 dBm: 1.8% <18 GHz. RF Connector Type: N (m). Maximum Input Power: 23 dBm, CW; 30 dBm, 1 µs peak, ±20 Vdc.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MA2472D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your ANRITSU MA2472D REPAIR and/or ANRITSU MA2472D 18 GHz Standard Diode Sensor CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: