ANRITSU MG9637A CALIBRATION and ANRITSU MG9637A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MG9637A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
   ANRITSU MG9637A   Description / Specification:    
ANRITSU MG9637A 1500 to 1580 nm Tunable Laser Source

The Anritsu The MG9637A Tunable Laser Source is designed to meet excellent wavelength repeatability, it is achieved by self-calibration and improved reliability using a new external cavity technology. The MG9637A utilize an external optical automatic power control (APC) module, the MG9637A has an Lithium Niobate modulator in the APC section to provide excellent output power stability and S/N ratio. The power of Output 1 of the MG9637A has been stabilized to ±0.01 dB using the APC function, permitting easy and stable wavelength loss measurement of optical devices. In addition, the wavelength flatness is within ±0.1 dB, enabling high-accuracy measurement of wavelength loss without normalization of the output power of the laser source. The coherence control function broadens the linewidth to about 50 MHz eliminating level fluctuations due to interference and permitting accurate measurement. Specifications. Wavelength range: 1500 to 1580 nm. Wavelength setting resolution: 1 pm. Absolute wavelength accuracy: <±0.1 nm. Wavelength stability: <±100 MHz/h. Wavelength repeatability: ±35 pm (80 nm range), Typical: ±7 pm (at ±3 nm, after calibration). Side mode suppression ratio: >45 dB (1520 to 1570 nm), >40 dB (1500 to 1580 nm). Linewidth (typical value): 700 kHz (coherent control: Off), 50 MHz (coherent control: On). Wavelength switching time (typical value): 100 ms/1 nm, 150 ms/10 nm, 500 ms/80 nm. Output 1 Max. output power: >–10 dBm (1520 to 1570 nm), >–13 dBm (1500 to 1580 nm). Output 2 Output power: >–10 dBm. Internal modulation: 200 Hz to 20 kHz (square waveform), Duty: 50%.



 

Standard Calibration $275.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MG9637A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Time
Average time for the wave train to lose its phase realtionships

Fiber Bragg Grating (FBG)
A fiber Bragg grating (FBG) is a type of distributed Bragg reflector constructed in a short segment of optical fiber that reflects particular wavelengths of light and transmits all others. This is achieved by adding a periodic variation to the refractive index of the fiber core, which generates a wavelength specific dielectric mirror. A fiber Bragg grating can therefore be used as an inline optical filter to block certain wavelengths, or as a wavelength-specific reflector.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another. Adding information into pulses of light.

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, such as a fiber optic transmission system, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your ANRITSU MG9637A CALIBRATION and/or ANRITSU MG9637A 1500 to 1580 nm Tunable Laser Source REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: