ANRITSU MS2719B CALIBRATION and ANRITSU MS2719B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2719B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   ANRITSU MS2719B   Description / Specification:    
ANRITSU MS2719B 20 GHz Microwave Spectrum Analyzer

The Anritsu MS2719B 9 kHz to 20 GHz, Synthesized Spectrum Analyzereasily handles most RF and microwave spectrum analyzer needs. A wide 10 MHz demodulation bandwidth supports optional GSM, CDMA, W-CDMA, W-CDMA/HSDPA, EVDO, WiMAX and TD-SCDMA measurements. 512 MB Storage for 4,000 Traces and 4,000 Setups. Standard Built-in Preamplifier. Specifications. Frequency Range: 9 kHz to 20.0 GHz. Preamplifier: 100 kHz to 4.0 GHz. Frequency Span: 10 Hz to full frequency range, plus 0 Hz (zero span). Tuning Resolution: 1 Hz. Amplitude accuracy at 50 MHz: ± 0.7 dB (20° C to 30° C). Attenuator Range: 0 to 65 dB. Attenuator Resolution: 5 dB steps. Measurement Range: DANL to +30 dBm. Display Range: 1 to 15 dB/div in 1 dB steps Ten divisions displayed. Resolution Bandwidth: (–3 dB) 1 Hz to 3 MHz in 1-3 sequence ±10%, 200 Hz, 9 kHz, 120 kHz when quasi-peak detector selected. Sweep Time Zero span: 10 us to 600s. Display: 8.4 inch Color TFT Display (SVGA). Options. 001 - Rack Mount. 007 - Secure Data Operation. 009 - RF and Demodulation Hardware. 017 - GPIB Interface. 019 - High Accuracy Power Meter Functionality. 089 - IF Output.



 

Standard Calibration $655.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS2719B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your ANRITSU MS2719B CALIBRATION and/or ANRITSU MS2719B 20 GHz Microwave Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: