ANRITSU MS9710B REPAIR and ANRITSU MS9710B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANRITSU MS9710B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS9710B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   ANRITSU MS9710B   Description / Specification:    
ANRITSU MS9710B 600 to 1750 nm Diffraction-grating Optical Spectrum Analyzer

The Anritsu MS9710B is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 0.6 to 1.75 µm wavelength band. In addition to uses such as measurement of LD and LED spectra, it has functions for measuring the transmission characteristics of passive elements such as optical isolators, as well as the NF/Gain of optical fiber systems. The MS9710B has achieved an improved S/N over a wide range by taking thorough countermeasures to noise and stray light. The RMS noise level at wavelengths from 1.25 to 1.6 µm is -90 dBm max. Specifications. Wavelength: 600 nm to 1750 nm. Wavelength accuracy: ±0.2 nm (after Wcal (Ext), ±0.3 nm (600 to 1750 nm). Sweep Width: 0.2 to 1200 nm, 0 nm. Resolution accuracy: 1550 ±20 nm Center Wavelengths. Dynamic range of 70 dB (1 nm from peak wavelength), 60 dB (0.5 nm from peak wavelength). Option. Option 02: White light source. Option 05: Reference wavelength light source. Option 13: Wavelength reference & SLD light source. Option 14: SLD light source.



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $1,025.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS9710B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
Optical power referenced to 1 millimatt

Multimode Fiber
Multimode Fiber has a large core (almost always 62.5 microns - a micron is one one millionth of a meter - but sometimes 50 microns) and is used with LED sources at wavelengths of 850 and 1300 nm for short distance, lower speed networks like LANs. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Refractive Index
The refractive index or index of refraction of a substance is a measure of the speed of light in that substance. It is expressed as a ratio of the speed of light in vacuum relative to that in the considered medium. The velocity at which light travels in vacuum is a physical constant, and the fastest speed at which energy or information can be transferred. However, light travels slower through any given material, or medium, that is not vacuum.

Total insertion loss
A measure of the loss of light within an optical component


Please contact us for your ANRITSU MS9710B REPAIR and/or ANRITSU MS9710B 600 to 1750 nm Diffraction-grating Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: