BOONTON 57540 CALIBRATION and BOONTON 57540 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BOONTON 57540 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   BOONTON 57540   Description / Specification:   Spec Sheet 
BOONTON 57540 40 GHz Peak Power Sensor

The Boonton 57540 Peak Power Sensor is constructed using balanced diode detectors. This dual diode configuration offers increased sensitivity and harmonic suppression when compared to a single diode sensor. It is for use with models 4400, 4500, 4400A, 4500A, 4530 and 4540. Specifications. Frequency Range: 0.05 to 40 GHz. Peak Power Range(For pulse signal only): -40 to +20 dBm. CW Power Range: -50 to +20 dBm. Int. Trigger Range: -27 to +20 dBm. Overload Rating Pulse: 1 W for 1µs. Overload Rating Continuous: 200 mW. Sensor Response Fast Risetime: < 100 ns (Bandwidth 6 MHz). Sensor Response Slow Risetime: < 10 ns (Bandwidth 350 kHz). Maximum SWR: 0.05 to 4 GHz, 1.25; 4 to 38 GHz, 1.65; 38 to 40 GHz, 2.00. Impedance: 50 ohm. RF Connector: Type K (M).



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BOONTON 57540. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your BOONTON 57540 CALIBRATION and/or BOONTON 57540 40 GHz Peak Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: