DATRON 4708 CALIBRATION and DATRON 4708 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DATRON 4708 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   DATRON 4708   Description / Specification:    
DATRON 4708 Autocal Multifunction Standard

The Datron 4708 Autocal Multifunction Standard offers the very best in programmable multifunction performance. Capable of calibrating-BY ITSELF-the latest generation of high performance systems and standards DMMs, it represents the most practical and cost-effective solution to today's high accuracy calibration requirements. The Model 4708 employs Autocal, the electronic adjustment technique whereby all calibration adjustments are made through the use of digital corrections stored in non-volatile memory. The instrument is calibrated by applying the standard and following a simple sequence of front panel keystrokes or IEEE-488 bus commands. Moreover, the signal generation circuit configuration employed during calibration is the same as that used during normal operation, ensuring fast, traceable, repeatable calibration. DC Voltage (Option 10); Ranges: 100 uV to 1000V in decades. Full scale: 2 x range except 1000V range, where max output is 11OOV. Resolution: 1 digit in 19,999,999 or 10 nV, whichever is greater. Sensing: Selectable remote/local sensing on 1 V to 1000V ranges. Guarding: Selectable remote/ local guarding. Settling Time: < 1 s to 10 ppm of step size. Output Impedance/Max Output Current: 100 uV to 100 mV Ranges, 100 ohm. 1V to 1000V Ranges, 25 mA max. AC Voltage (Option 20); Ranges: 1 mV to 1000V in decades. Full Scale: 2 x range except 1000V range, where max output is 1100V. Resolution: 1 digit in 1,999,999 or 100 nV, whichever is greater. Frequency: Ranges: 100 Hz to 1 MHz in decade steps. Resolution: 1 % of range. Accuracy: <±100 ppm. Sensing: Selectable remote/local senSing on 1V to 1000V ranges. Guarding: Selectable remote/local guarding. Maximum Capacitive load: 1000 pF on 1 V to 100V ranges, 300 pF on 1000V range. Settling Times: To 100 ppm of step size: <10s (10-32 Hz), <3 s (33-330 Hz), <1 s (>330 Hz). DC Current (Option 30); Ranges: 100 uA to 1A in decades. Full scale: 2 x range. Resolution: 1 digitin 1,999,999 or 100 pA, whichever is greater. Guarding: Selectable remote/local guarding. AC Current (Option 30); Ranges: 100 mA to 1A in decades. Full Scale: 2 x range. Resolution: 1 digit in 1,999,999 or 100 pA, whichever is greater. Guarding: Selectable remote/local guarding. Resistance (Option 30); Ranges: 10 ohms to 100 M-ohm in decades. (Ranges are nominal, actual calibrated values are displayed). Connections: Selectable 2 or 4-wire, remote/local guard. Display Resolution: 1 digit in 19,999,999. IEEE-488 interface. OPTIONS; 10: DCV Ranges. 20: ACV Ranges. 30: DCI, ACI and Resistance Ranges (requires Option 10, or 20, or both). 42: Alternative Rear Output. 80: 115V 60Hz line operation. 81: 115V 50Hz line operation.



 

Standard Cal with Data $1,305.00 *
*This is a Web introductory price for one calibration of the DATRON 4708. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your DATRON 4708 CALIBRATION and/or DATRON 4708 Autocal Multifunction Standard REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: