EIP 25B CALIBRATION and EIP 25B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EIP 25B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   EIP 25B   Description / Specification:    
EIP 25B CW Frequency Counter

The EIP 25B is a microprocessor-based microwave frequency counter that measures the frequency and power of CW signals. The frequency range of the 25B is from 10 Hz to 20 GHz. Frequency measurements are divided into three bands. Power meaurements can only be made in Band 3. Band 1 is a high impedance input (1 MOhm/20pF) and covers frequency range from 10 Hz to 100 MHz, with a sensitivity of 25 mV rms. Band 2 has an input impedance of 50 ohms and covers the frequency range from 10 MHz to 1 GHz, with a sensitivity of -20 dBm. Band 3 has an input impedance of 50 Ohms and covers the frequency range from 1 GHz to 20 GHz, with a sensitivity of -30 dBm from 1 GHz to 12.4 GHz and a sensitivity of -25 dBm from 12.4 to 20 GHz. Through keyboard control and remote operation via the general purpose interface bus (GPIB), the EIP 25B counter provides frequency features such as offsets, frequency multiplication, center frequency, and frequency limits. A high stability time base is available as an option.Measurements are presented on a 12-digit LED display that is sectionalized to read directly in GHz, MHz, kHz, and Hz.



 

Standard Calibration $405.00 *
*This is a Web introductory price for one calibration of the EIP 25B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your EIP 25B CALIBRATION and/or EIP 25B CW Frequency Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: