A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 27 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 27   Description / Specification:    
FLUKE 27 Autoranging MultiMeter

The Fluke 27 analog/digital multimeter combines accurate digital and analog measurement capability with extreme ruggedness and durability. They have cases twice as thick as any other Fluke DMM, performing under the extremes of heat, cold, humidity, shock, electromagnetic interference, vibration and downright abuse. It features a 3200-count digital display for accuracy and resolution, a 31-segment analog bar graph for fast peaking, nulling zero adjustments and capacitor checking, plus fast autoranging and manual ranging. The TouchHold® function captures and locks the measurement and automatically updates with the next measurement. It has conductance for high resistance measurement and Min/Max and Relative modes.
Specifications.

DC Voltage.
Range and Resolution: 320.0 mV, 3.200V, 32.00V, 320.0V, 1000V.
Best Accuracy: ±(0.1%+1).

AC Voltage.
Range and Resolution: 320.0 mV, 3.200V, 32.00V, 320.0V, 1000V.
Best Accuracy: ±(0.5%+3).

DC Current.
Range and Resolution: 320.0 µA, 3200 µA, 32.00 mA, 320.0 mA, 10.00A.
Best Accuracy: ±(0.75%+2).

AC Current.
Range and Resolution: 320.0 µA, 3200 µA, 32.00 mA, 320.0 mA, 10.00A.
Best Accuracy: ±(1.5%+2).

Resistance.
Range and Resolution: 320.0 Ω, 3.200 kΩ, 32.00 kΩ, 320.0 kΩ, 3.200 MΩ, 32.00 MΩ.
Best Accuracy: ±(0.2%+1).

Conductance.
Range and Resolution: 32.00 nS.
Best Accuracy: ±(2%+10).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE 27 CALIBRATION and/or FLUKE 27 Autoranging MultiMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: