FLUKE 36 CALIBRATION and FLUKE 36 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 36 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 36   Description / Specification:    
FLUKE 36 1000A AC/DC Clamp Meter

The Fluke 36 AC/DC Clamp Meter is a rugged, reliable meter that measures ac and dc current and volts. This versatile clamp meter offers true-rms sensing and MAX Hold for measuring inrush current or maximum load on a circuit. Tapered jaws and slim profile let you get at cables in tight places. Use it for troubleshooting in industrial, commercial, avionics and marine environments. Features. Jaws accept one 750 MCM (1.2" (3 mm)) cable or two 500 MCM (0.98" (2.46 cm)) cables up to 38 mm (1.5" in diameter). DC current zero control for nulling out jaw/sensor offset. Easy, single-handed operation. Easy-view 2000 count digital display. Continuity beeper. Sleep mode extends battery life. True-rms responding. 3 1/2 digit, 2000 count display. Specifications. DC Current Range 1000 A: Resolution: 1 A, Accuracy: 0 to 600 A ±(1.9% + 4), 600 to 1000 A ±(3% + 3). DC Current Range 200 A: Resolution: 0.1 A, Accuracy: ±(1.9% + 7). DC Volts Range 600/200 V: Resolution: 1 V / 0.1 V, Accuracy: ±(1.0% + 3). AC Current Range 600 A (45-400Hz): Resolution: 1 A, Accuracy: 10 to 600 A ±(2% + 3). AC Current Range 200 A (45-400Hz): Resolution: 0.1 A, Accuracy: 0.5 to 200 A ±(2% + 5). AC Volts Range 600/200 V (45-400Hz): Resolution: 1 V / 0.1 V, Accuracy: ±(1.5% + 3). Resistance Range: 200 ohm. Resistance Accuracy: ±(1.2% + 5). Resistance Resolution: 0.1 ohm.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 36. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 36 CALIBRATION and/or FLUKE 36 1000A AC/DC Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: