FLUKE 52 CALIBRATION and FLUKE 52 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 52 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Temperature Recording / Thermometer?
Shop for Comparable Products on our
 used Temperature Recording / Thermometer page

 
   FLUKE 52   Description / Specification:    
FLUKE 52 Dual Input Type J/K Digital Thermometer

The Fluke 52 Dual-input Digital Thermometer is designed for high accuracy and resolution with excellent repeatability. Dual inputs (T1 and T2) allow two individual points to be monitored, and provide information for the differential mode (T1 minus T2). A MIN/MAX register is available for any input (T1, T2, or T1 -T2). At power-up the user can select a "scan" mode, which scrolls through the three modes in a T1, T2, T1-T2 continuous sequence. Also selectable at power-up is the choice of high resolution (0.1 °C or 0.2°F) or low resolution (1° C or 1° F) readouts. Specifications. Temperature Scale: Celsius or Fahrenheit user-selectable. Resolution: 1° C or 1° F (or 0.1° C or 0.2°F) user-selectable. Thermocouple Types: K-type or J-type that conform to NBS and IEC 584 tables, user-selectable. Measurement Range: K-type range is -200° C to 1370° C (-328° F to 2498° F). J-type range is -200° C to 760° C (-328° F to 1400° F). Also check the rated range of the thermocouple to be used. Meter Operating Range: For use in 0° C to 50° C environment (32° F to 122° F). Temperature Coefficient: Within the meter operating range, add to the meter accuracy specification 0.01% of reading + 0.03 degrees for each degree below 18° C (64° F) or above 28° C (82° F). Maximum Input: 60V dc or 24V rms ac between the input pins or any input and ground. Reading Rate: 1 second per reading for one probe, 1.7 seconds per reading in the scan mode.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 52. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


 

Please contact us for your FLUKE 52 CALIBRATION and/or FLUKE 52 Dual Input Type J/K Digital Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: