FLUKE 73 CALIBRATION and FLUKE 73 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 73 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 73   Description / Specification:    
FLUKE 73 3 1/2 Digit Handheld Multimeter

The Fluke 73 Handheld Multimeter provides a 3200 count digital display that gives extended resolution, and a 32 segment analog bar graph that reacts 10 times faster than the numerical display, allowing you to make peaking and dipping adjustments easier. With autoranging, you choose the function you want and the meter automatically selects the range with the greatest accuracy and resolution. A continuous audible tone provides a fast check for continuity of current paths having 150 ohms or less. A brief tone indicates a voltage drop of about 0.6 volts, the normal forward bias for semiconductor devices passing about 500 microamps.
Specifications.

DC Voltage.
Range: 320 mV to 1000 V.
Resolution: 0.1 mV to 1 V.
Accuracy: 0.7% +/- 1.

AC Voltage.
Range: 3.2 V to 750 V.
Resolution: 1 mV to 1 V.
Accuracy: 3% +/- 2.

DC Current.
Range: 32 mA to 10 A.
Resolution: 0.01 mA to 10 mA.
Accuracy: 2% +/- 2.

AC Current.
Range: 32 mA to 10 A.
Resolution: 0.01 mA to 10 mA.
Accuracy: 3% +/- 2.

Resistance.
Range: 320 Ω to 32 MΩ.
Resolution: 0.1Ω to 10 kΩ.
Accuracy: 1% +/- 2, 1% +/- 1, 3% +/-1.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your FLUKE 73 CALIBRATION and/or FLUKE 73 3 1/2 Digit Handheld Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: