A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 83 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 83   Description / Specification:    
FLUKE 83 Handheld Digital Multimeter

The Fluke 83 Handheld Digital Multimeter is a 4000 count digital instrument for use in the laboratory, field, and home. The meter combines the precision of a digital meter with the speed and versatility of a high resolution bar graph, featuring a zoom function that increases sensitivity by a factor of 10. Frequencies between 0.5 Hz and 200 kHz can be measured with up to 0.01 Hz resolution. The meter also provides a Min/Max recording mode, an alternate frequency counter that measures duty cycle, Input Alert, and Relative, Touch Hold, and Capacitance modes.
Specifications.

DC Voltage.
Range: 400 mV to 1000 V.
Resolution: 0.1 mV to 1 V.

AC Voltage.
Range: 400 mV to 1000 V.
Resolution: 1 mV to 1 V.

Resistance.
Range: 400 Ω to 40 MΩ.
Resolution: 0.1Ω to 10 kΩ.

Capacitance.
Range: 5 nF to 5 µF.
Resolution: 0.01 nF to 0.01 µF.

DC/AC Current.
Range: 40 mA to 10 A.
Resolution: 0.01 mA to 0.01 A.
Accuracy: 2% +/- 2.

Frequency.
Range: 199.9 Hz to >200 kHz.
Resolution: 0.01 Hz to 0.1 kHz.
Accuracy: 0.005% +/- 1.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 83 CALIBRATION and/or FLUKE 83 Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: