FLUKE 87 CALIBRATION and FLUKE 87 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 87 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 87   Description / Specification:    
FLUKE 87 Handheld True RMS Digital Multimeter

The Fluke 87 4000-count DMM provides 11 functions for electronic and industrial applications, including high performance dc/ac voltage and current measurement, frequency, duty cycle, resistance, conductance, and capacitance measurement. It is EMI shielded and comes with a splash-proof and dust-proof case. A protective holster enables safe use under harsh operating conditions. Features. Min/Max/Average recording mode with Min/Max AlertTM; stores the highest, lowest and 36-hour average of all readings, allowing signal monitoring for seconds or days. Min/Max Alert gives an audible tone for readings above or below previous minimums or maximums. Frequency, duty cycle and capacitance measurements. 1000V rms input protection; Input Alert provides an audible warning if the test leads are in current, but the function switch is not. This reduces the risk of damage to the equipment being tested and to the meter. Provides 1000 volt rms input protection in both ohms and diode test. 3%-digit, 4000 count display updates 4 times per second, analog display updates 40 times per second. 4.5-digit mode, 19 999 counts and True-rms ac voltage and current. Ranges. VDC: 400 mV - 1000V. VAC: 400 mV - 1000V. ADC 400 uA - 10 A. AAC: 400 uA - 10 A. Resistance: 400 ohm - 40 M-ohm. Conductance: 40 nS. Capacitance: 5 nF- 5 uF. Frequency: 199.9 Hz -199.9 kHz.



 

Standard Calibration $60.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 87. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 87 CALIBRATION and/or FLUKE 87 Handheld True RMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: