FLUKE 111 CALIBRATION and FLUKE 111 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 111 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 111   Description / Specification:    
FLUKE 111 Handheld True RMS Digital Multimeter

The Fluke 111 true-rms multimeter has all the basic measurement features and functions needed for every day tasks. Their simplicity and compact design, make them perfect for quick verifications for field service and contractor use. Features. 600 V measurement range. True-rms for accurate measurements. 10 amps continuous. Resistance and continuity. Frequency and capacitance. Min/Max to record signal fluctuations. Meets measurement CAT III 600 V safety standards. Specifications. V DC Range: 6000 mV, 6.000 V, 60.00 V, 600.0 V. V DC Best Accuracy: ± 0.7 % of reading. V AC Range: 6000 mV, 6.000 V, 60.00 V, 600.0 V. V AC Best Accuracy: ± 1.0 % of reading. A DC Range: 6.000 A, 10.00 A. A DC Best Accuracy: ± 1.0 % of reading. A AC Range: 10.00 A. A AC Best Accuracy: ± 1.5 % of reading. Resistance Range: 600.0 ohm, 6.000 kohm, 60.00 kohm, 600.0 kohm, 6.000 Mohm, 40.00 Mohm. Resistance Best Accuracy: ± 1.5 % of reading. Capacitance Range: 1000 nF, 10.00 µF, 100.0 µF, 9999 µF. Capacitance Best Accuracy: ± 1.9 % of reading. Frequency Range (Voltage frequency is specified from 5 Hz to 50 kHz. Current Frequency is specified from 50 Hz to 5 kHz.): 99.99 Hz, 999.9 Hz, 9.999 Hz, 50.00 kHz. Frequency Best Accuracy: ± 0.1 % of reading.



 

Standard Calibration $65.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 111. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 111 CALIBRATION and/or FLUKE 111 Handheld True RMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: