FLUKE 115 CALIBRATION and FLUKE 115 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 115 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 115   Description / Specification:    
FLUKE 115 True RMS Multimeter

The Fluke 115 Multimeter for field service testing is an everyday multimeter for technicians, the 115 is optimized for electrical and electronic testing in field service, industrial, and applications where more than basic functionality (such as measurement of ac/dc current) simplifies working. Features: True RMS readings. 6000 Counts. Min/Max/Average to record signal fluctuations. Auto/manual ranging. Display hold. Specifications. Voltage DC Maximum: 600 V. Voltage DC Maximum Resolution: 1 mV. Voltage DC Best Accuracy: ±(0.5%+2). Voltage AC Maximum: 600 V. Voltage AC Maximum Resolution: 1 mV. Voltage AC Best Accuracy: ±(1.0%+3). Current DC Maximum: 10.00 A. Current DC Maximum Resolution: 1 mA. Current DC Best Accuracy: ±(1.0%+3). Current AC Maximum: 10.00 A. Current AC Maximum Resolution: 0.01 A. Current AC Best Accuracy: ±(1.5%+3). Resistance Maximum: 40 M-ohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Best Accuracy: ±(0.9%+1). Capacitance Maximum: 10000 µF. Capacitance Maximum Resolution: 1 nF. Capacitance Best Accuracy: ±(1.9%+2). Frequency Maximum: 50 kHz. Frequency Maximum Resolution: 0.01 Hz. Frequency Best Accuracy: ±(0.1%+2). Battery type: 9 volt Alkaline, 400 hours typical.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 115. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 115 CALIBRATION and/or FLUKE 115 True RMS Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: