FLUKE 335 CALIBRATION and FLUKE 335 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 335 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 335   Description / Specification:    
FLUKE 335 600 Amp AC Clamp Meter

The Fluke 335 is a standard Clamp Meter with a large backlight display. It measures ac amps, ac/dc volts, ohms, display hold and features motor start-up current. Auto shut-off maximizes battery life and makes sure the meter works when you need it. The slim, easy-to-grip body fits comfortably in your hand. The narrow jaws easily squeeze in and out of the tight spots. The large, backlit display makes measurements easy to see in any light. And if you need to troubleshoot current surges that can trip motor starters, choose a model with the inrush current function.
Specifications.

Voltage DC.
Range: 0 - 600.0 V.
Accuracy: 1% ± 5 counts.

Voltage AC.
Range: 0 - 600.0 V.
Accuracy: 1% ± 5 counts (50/60 Hz).
AC Response: True-rms.

Current AC.
Range: 0 - 600.0 A.
Accuracy: 2% ± 5 counts (50/60 Hz).
Crest Factor(50/60 Hz): 2.4 @ 500A, 2.0 @ 600A, add 2% for CF>2.
AC Response: True-rms.

Resistance.
Range: 0 - 600.0 Ω, 6001 - 6000 Ω.
Accuracy: 1.5% ± 5 counts.

Inrush Current.
Integration Time: 100 ms.

Continuity: <= 30 Ω.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 335 CALIBRATION and/or FLUKE 335 600 Amp AC Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: