FLUKE 902 CALIBRATION and FLUKE 902 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 902 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 902   Description / Specification:    
FLUKE 902 600 Amp HVAC Clamp Meter

The Fluke 902 HVAC Clamp Meter was designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements. The small body and jaws fit perfectly in your hand and into tight places, and the meter controls are positioned so current measurements can be done with one hand. It features a large, backlit display and an auto shut-off that maximizes battery life so the meter works when you need it. It is a True RMS meter with a CAT III 600 V safety rating.
Specifications.

Voltage DC.
Range: 0 - 600.0 V.
Accuracy: 1% ±5 counts.

Voltage AC (True RMS).
Range: 0 - 600.0 V.
Accuracy: 1% ±5 counts (50/60 Hz).

Current AC (True RMS).
Range: 0 - 600.0 A.
Accuracy: 2.0% ±5 counts (50/60 Hz).

Current DC.
Range: 0 - 200.0 µA.
Accuracy: 1.0% ±5 counts.

Resistance.
Range: 0 - 9999 Ω.
Accuracy: 1.5% ±5 counts.
Continuity: ≤ 30 Ω.

Temperature (Type K Thermocouple).
Range: -10°C to 400°C (-14°F to 752°F).
Accuracy: ±1.0% + 0.8°C (±1.0% + 1.5°F) typical.
Range: -40°C to -10°C (-40°F to -14°F).
Accuracy: ±5.0% + 1.5°C (±5.0% + 3.3°F) typical.

Capacitance.
Range: 1 - 1000 µF.
Accuracy: 1.9% ±2 counts.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 902. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE 902 CALIBRATION and/or FLUKE 902 600 Amp HVAC Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: