FLUKE 1625 CALIBRATION and FLUKE 1625 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 1625 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 1625   Description / Specification:   Spec Sheet 
FLUKE 1625 Advanced GEO Earth Ground Tester

The Fluke 1625 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. The Fluke 1625 features, Automatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value. Also, R* measurement - calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see. Specifications. Operating temperature: 0 °C to 35 °C (32 °F to 95 °F). Temperature coefficient: ± 0.1 % of reading/K. RA 3-pole ground resistance measurement (IEC 1557-5). Measuring range: 0.001 ohm to 19.99 kohm. Resolution: 0.001 ohm to 10 ohm. Intrinsic error: ± (2 % rdg + 3 d). Operating error: ± (5 % rdg + 3 d). RA 4-pole ground resistance measurement (IEC 1557-5). Measuring range: 0.001 ohm to 19.99 kohm. Resolution: 0.001 ohm to 10 ohm. Intrinsic error: ± (2 % rdg + 3 d). Operating error: ± (5 % rdg + 3 d). RA 3-pole selective ground resistance measurement with current clamp. Measuring range: 0.001 ohm to 19.99 kohm. Resolution: 0.001 ohm to 10 ohm. Intrinsic error: ± (7 % rdg + 3 d). Operating error: ± (10 % rdg + 5 d). RA 4-pole selective ground resistance measurement with current clamp. Measuring range: 0.001 ohm to 19.99 kohm. Resolution: 0.001 ohm to 10 ohm. Intrinsic error: ± (7 % rdg + 3 d). Operating error: ± (10 % rdg + 5 d). Stakeless ground loop measurement. Measuring range: 0.001 ohm to 19.99 kohm. Resolution: 0.001 ohm to 10 ohm. Intrinsic error: ± (7 % rdg + 3 d). Operating error: ± (10 % rdg + 5 d). Measurement of interference voltage dc + ac (UST). Measuring range: 1 V to 50 V. Resolution: 0.1 V. Frequency Range: dc/ac 45 Hz to 400 Hz sine. Limits of Error: ± (5 % rdg + 5 d). Measurement of interference frequency (F). Measuring range: 6.0 Hz to 400 Hz. Resolution: 0.1 Hz to 1 Hz. Range: 1 V to 50 V. Limits of Error: ± (1 % rdg + 2 d). Resistance measurement (R ac). Measuring range: 0.020 ohm to 300 kohm. Resolution: 0.001 ohm to 100 ohm. Intrinsic error: ± (2% rdg + 2 d). Operating error: ± (5 % rdg + 5 d). Resistance measurement (R dc). Measuring range: 0.020 ohm to 3 kohm. Resolution: 0.001 ohm to 1 ohm. Intrinsic error: ± (2% rdg + 2 d). Operating error: ± (5 % rdg + 5 d).



 

Standard Calibration $490.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 1625. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your FLUKE 1625 CALIBRATION and/or FLUKE 1625 Advanced GEO Earth Ground Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: