FLUKE 124 CALIBRATION and FLUKE 124 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 124 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   FLUKE 124   Description / Specification:    
FLUKE 124 ScopeMeter 40 MHz Portable Oscilloscope

The Fluke 124 ScopeMeter is a 40 MHz Portable Oscilloscope For industrial, electronic or electro mechanical applications, the compact Fluke 124 Industrial ScopeMeter is the rugged solution for industrial troubleshooting and installation applications. It features 20MHz bandwidth, Connect-and-View triggering automatically displays stable waveforms of virtually any signal and a dual DMM and a paperless recorder to get virtually any job done.
Features:

Dual-input 40 MHz digital oscilloscope.
Two 5,000-count true-rms digital multimeters.
10 save setups and screens.
A dual-input TrendPlot recorder.
Connect-and-View trigger simplicity for hands-off operation.
Shielded test leads for oscilloscope, resistance, continuity and capacitance measurements.

Specifications.

Vertical.
Frequency Response.
DC Coupled.
  DC to 40 MHz (-3 dB).
  DC to 12.5 MHz (-3 dB).
  DC to 20 MHz (-6 dB).
AC Coupled (LF roll off).
excluding probes and test leads: <10 Hz (-3 dB).
with STL120: <10 Hz (-3dB).
with 10 MΩ 10:1 Probe: <1 Hz (-3 dB).
Rise Time: <17.5 ns.
Input Impedance: 1 MΩ//12 pF
Sensitivity: 5 mV to 500 V/div.
Display Modes: A, -A, B, -B.
Max. Input Voltage A and B
direct, with test leads, or with VP40 Probe: 600 Vrms.
with BB120: 300 Vrms.
Max. Floating Voltage: 600 Vrms up to 400 Hz.
Resolution: 8 bit.
Vertical Accuracy: ±(1% + 0.05 range/div).
Max. Vertical Move: ±4 divisions.

Horizontal.
Scope Modes: Normal, Single, Roll.
Ranges.
Normal.
  equivalent sampling: 10 ns to 500 ns/div.
  real time sampling: 1 μs to 5 s/div.
Single (real time): 1 μs to 5 s/div.
Roll (real time): 1s to 60 s/div.
Sampling Rate.
  Equivalent sampling (repetitive signals): up to 1.25 GS/s.
  Real time sampling.
  1 μs to 5 ms/div: 25 MS/s.
  10 ms to 60 s/div: 5 MS/s.
Time Base Accuracy.
Equivalent sampling: ±(0.4% +0.04 time/div).
Real time sampling: ±(0.1% +0.04 time/div).
Glitch Detection.
  ≥40 ns @ 20 ns to 5 ms/div.
  ≥200 ns @ 10 ms to 60 s/div.
Horizontal Move: 10 divisions.



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 124. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 124 CALIBRATION and/or FLUKE 124 ScopeMeter 40 MHz Portable Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: