FLUKE 5101B CALIBRATION and FLUKE 5101B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5101B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5101B   Description / Specification:    
FLUKE 5101B Five-function Calibrator, AC/DC Voltage AC/DC Current Resist

The Fluke 5101B is a five-function calibrator built for electrical calibration and has a built-in cassette tape deck to store calibration procedures. It calibrates analog and digital multimeters to 4.5 digits, precision meters that measure ac or dc voltage (0-1100V), ac or dc current (200 uA-2A), and resistance (1 ohm to 10 Mohms).
Specifications.

Voltage DC Ranges/ Resolution:
  20 mV / 0.1 μV,
  200 mV / 1 μV,
  2 V / 10 μV,
  20 V / 100 μV,
  200 V / 1 mV,
  1100 V / 10 mV.
Uncertainty: ±(0.004% of setting +0 .001 % of range +5 μV) for all ranges, for 6 months, 20°C to 30°C ambient, non-override; ±(0.005% of setting +0.2 mV) for divider override mode.

Voltage AC Ranges/ Resolution:
  20 mV / 0.1 μV,
  200 mV / 1 μV,
  2 V / 10 μV,
  20 V / 100 μV,
  200 V / 1 mV,
  1100 V / 10 mV.
Uncertainty: ±(0.035% of setting +0.005% of range +50 μV) from 50 Hz to 10kHz and ±(0.06% of setting +0.008% of range +50 μV) from 10kHz to 50 kHz for 6 months, 20°C to 30°C ambient.
Frequencies Available (Hz): 50, 60, 70, 80, 90, 100, 200, 300, 400, 500, 600, 700, 800, and 900 for all voltage ranges.

Current DC Ranges/ Resolution:
  200 μA / 1 nA,
  2 mA / 10 nA,
  20 mA / 100 nA,
  200 mA / 1 μA,
  2 A / 10 μA.
Uncertainty: ±0.015% of setting +0.002% of range +0.01 μA) for compliance voltage up to 1 V; Add 0.002% of setting per volt above 1 V rms; Applies for 6 months and 20°C to 30°C ambient

Current AC Ranges/ Resolution:
  200 μA / 1 nA,
  2 mA / 10 nA,
  20 mA / 100 nA,
  200 mA / 1 μA,
  2 A / 10 μA.
Uncertainty: ±0.05% of setting +0 .005% of range +0.02 μA) for compliance voltage up to 1 V rms (50 Hz to 1 kHz). Add 0.005% of setting per volt above 1 V rms. Applies for 6 months in 20°C to 30°C ambient.

Resistance:
Range: 1 Ω to 10 MΩ in decade steps.
Uncertainty: ±0.003%, except ±0.015% (1 Ω), ±0.010% (10 Ω and 1 MΩ), and ±0.030% (10 MΩ) assumes 4 terminal below 100 kΩ. 6 mo 20°- 30°C.
Power Dissipation: 1W maximum except 100 mW max (1 MΩ) and 10 mW max (10 MΩ).

Options.
-03 Wide band AC Voltage.
-05 IEEE-488 Compatible Interface.
-06 EIA RS-232-C Interface.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5101B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your FLUKE 5101B CALIBRATION and/or FLUKE 5101B Five-function Calibrator, AC/DC Voltage AC/DC Current Resist REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: