FLUKE 5200A CALIBRATION and FLUKE 5200A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5200A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5200A   Description / Specification:    
FLUKE 5200A Precision Alternating Voltage Calibrator

The Fluke 5200A Precision Alternating Voltage Calibrator is a precision high-performance alternating voltage source with proven reliability and exceptional stabi lity and accuracy over a broad frequency range. It is specified over a wide 0°C to 50°C operating range for use in both laboratory and manufacturing environments. Amplitude is controlled in six ranges from 1 mV to 100 V. Resolution to 1,199,999 counts yields 20% overrange capability with 1 nanovolt steps on the 1 mV range, up to 0.1 mV steps on the 100 V range. Outputs from 100 µV RMS to 120 V RMS are provided, with up to 50 mA load current capability. An additional 1000 V range is included for front panel or remote interface control of a 5205A or 5215A Precision Power Amplifier. Amplitude error measurement for voltmeter calibration is provided in two ranges, ±3% and ±0.3%. Error measurements can be resolved to 10 ppm. Five frequency ranges are provided from 100 Hz to 1 MHz, with 119,999 count resolution for 20% overrange capability with 0.01 Hz steps on the 100 Hz range, up to 100 Hz steps on the 1 MHz range. The oscillator of the 5200A may be phase locked to an external source to produce synchronous signals of precision amplitude and stability. Signal phase is locked within ±1° a of phase angle, ±0.05°/kHz, over a ±2% band around the center frequency. This capability is essential for 50 Hz calibration. A 3V pulse signal is provided for monitoring frequency with an external counter. A quadrature output signal is provided which leads the fundamental signal phase by 90°. Amplitude varies from 1 V to 10 V rms, proportional to the fundamental signal output level on any range. This signal is useful for wattmeter calibration, and for research and development tasks that use the 5200A as a precision source.



 

Standard Calibration $950.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5200A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 5200A CALIBRATION and/or FLUKE 5200A Precision Alternating Voltage Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: