FLUKE 5500A-COIL CALIBRATION and FLUKE 5500A-COIL REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5500A-COIL Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration Standard? Shop for Comparable Products on our   new Calibration Standard page

 
   FLUKE 5500A-COIL (5500A/COIL)   Description / Specification:    
FLUKE 5500A-COIL 50 Turn Current Coil

The Fluke 5500A/COIL is a 50-Turn Current Coil used as a tool for calibrating clamp-type current meters that operate by two different principles-as current transformers (AC only), and by the Hall Effect (Both AC and DC).
Specifications.

Number of Turns: 50.
Maximum Current: 11A rms, continuous (20.5A rms, 2 minutes).
Maximum Duty Cycle Derating: < 11A, continuous (> 11A, 2 minutes ON, 8 minutes OFF).
Maximum Voltage: 7 V dc or 7 V rms ac.
Minimum Inner Diameter of Clamp Jaws: 2.54 cm [1”].



Looking for a replacement? Try the  TRANSMILLE EA002

Standard Calibration $530.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5500A-COIL. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your FLUKE 5500A-COIL CALIBRATION and/or FLUKE 5500A-COIL 50 Turn Current Coil REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: