Custom-Cal has a high success rate in the repair of the FLUKE 5700A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5700A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5700A   Description / Specification:    
FLUKE 5700A Five-function Calibrator

The Fluke 5700A is a five-function calibrator built for electrical calibration. It sources direct and alternating voltage and current and resistance. A wideband voltage option extends overall ac bandwidth to 10 Hz to 30 MHz to cover to RF voltmeters. It is compatible with the 5725A, and 5205A/5215A amplifiers.
Specifications.

Voltage DC;
  Ranges: 0 to ±1100V.
  Best 1 Year Specification: ±7.0 ppm of setting.

Voltage AC;
  Ranges: 220 mV to 1100 V, 10 Hz to 1 MHz.
  Best 1 Year Specification: ±75.0 ppm of setting.

Resistance;
  Ranges: 0 to 100 M-ohm, 18 values in x1 and x1.9.
  Best 1 Year Specification: ±12.0 ppm of setting.

Current DC;
  Ranges: 0 to ±2.2A (11A with 5725A).
  Best 1 Year Specification: ±50.0 ppm of setting.

Current AC;
  Ranges: 9 uA to 2.2A (11A with 5725A) 10 Hz to 10 kHz.
  Best 1 Year Specification: ±140.0 ppm of setting.

Wideband AC Voltage Option;
  Ranges: 300 uV to 3.5V, 10 Hz to 30 MHz.
  Option Best 1 Year Specification: ±0.4% of setting.

Options:
5500A/COIL 50 Turn Current Coil.
5700A-03 Wideband AC Voltage.
5725A Amplifier increases maximum direct and alternating current to 11A.



 

Standard Cal with Data $1,565.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5700A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 5700A REPAIR and/or FLUKE 5700A Five-function Calibrator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: