FLUKE 5700A REPAIR and FLUKE 5700A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE 5700A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5700A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5700A   Description / Specification:    
FLUKE 5700A Five-function Calibrator

The Fluke 5700A is a five-function calibrator built for electrical calibration. It sources direct and alternating voltage and current and resistance. A wideband voltage option extends overall ac bandwidth to 10 Hz to 30 MHz to cover to RF voltmeters. It is compatible with the 5725A, and 5205A/5215A amplifiers.
Specifications.

Voltage DC;
  Ranges: 0 to ±1100V.
  Best 1 Year Specification: ±7.0 ppm of setting.

Voltage AC;
  Ranges: 220 mV to 1100 V, 10 Hz to 1 MHz.
  Best 1 Year Specification: ±75.0 ppm of setting.

Resistance;
  Ranges: 0 to 100 M-ohm, 18 values in x1 and x1.9.
  Best 1 Year Specification: ±12.0 ppm of setting.

Current DC;
  Ranges: 0 to ±2.2A (11A with 5725A).
  Best 1 Year Specification: ±50.0 ppm of setting.

Current AC;
  Ranges: 9 uA to 2.2A (11A with 5725A) 10 Hz to 10 kHz.
  Best 1 Year Specification: ±140.0 ppm of setting.

Wideband AC Voltage Option;
  Ranges: 300 uV to 3.5V, 10 Hz to 30 MHz.
  Option Best 1 Year Specification: ±0.4% of setting.

Options:
5500A/COIL 50 Turn Current Coil.
5700A-03 Wideband AC Voltage.
5725A Amplifier increases maximum direct and alternating current to 11A.



 

Standard Cal with Data $1,800.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5700A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 5700A REPAIR and/or FLUKE 5700A Five-function Calibrator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: