FLUKE 6060B CALIBRATION and FLUKE 6060B REPAIR

The FLUKE 6060B is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 6060B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   FLUKE 6060B   Description / Specification:    
FLUKE 6060B 1050 MHz Synthesized RF Signal Generator

The Fluke 6060B Synthesized RF Signal Generator is a solution for most general purpose RF testing needs. Built-in diagnostics and error code displays provide immediate feedback of incorrect operation. Also, the generator performs a series of internal digital and analog tests at power-up and isolate problem areas immediately via a coded display on the front panel. These internal checks may be accessed and initiated at any time from the front panel. Special service and troubleshooting test routines are contained within the unit to aid in calibration and maintenance. Specifications. Frequency Range: 0.01 to 1050 MHz. Resolution: 10 Hz. Switching Speed: <100 ms to be within 100 Hz of final frequency. Reference Output Frequency: 10 MHz, sinewave; Level: 0 dBm min into 50 ohm; Source Impedance: 50 ohm nominal. External Reference Input Frequency: 1, 2, 2.5, 5, 10 MHz; Input Level: 0.3 to 4V pk-pk, sinewave or squarewave; Input Impedance: 50 ohm nominal. Amplitude Range: -127 to + 13 dBm (+ 13 dBm peak on AM), with overrange to + 19 dBm and underrange to -147 dBm. Amplitude Resolution: 0.1 dB. Output VSWR: < 1.5:1 for amplitude <+ 1 dBm, < 2.0:1 for amplitude >+ 1 dBm. Amplitude Switching Speed: <100 ms typical (within 0.1 dB of selected value). Level Flatness: ±0.5 dB. AM Depth: 0 to 99% in 1% steps. AM Accuracy: ±(2% + 4% of setting). Frequency Modulation Deviation Ranges: 100 to 999 Hz, 1 to 9.99 kHz, 10 to 99.9 kHz. FM Deviation Accuracy: ±7% for rates of 0.3 to 20 kHz for carrier frequency greater than 400 kHz, FM deviation > 100 Hz. AF Bandwidth: 0.02 to 100 kHz (3 dB). Distortion: Less than 1 % THD for 0.3 to 20 kHz rates, FM deviation> 100 Hz (effects of Residual FM excluded). Options. Option -130: High Stability Crystal Oscillator. Option -132: Medium Stability Crystal Oscillator. Option -488: IEEE-488 Compatible Interface.



 

Standard Calibration $720.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 6060B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your FLUKE 6060B CALIBRATION and/or FLUKE 6060B 1050 MHz Synthesized RF Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: