FLUKE 7261A CALIBRATION and FLUKE 7261A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 7261A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   FLUKE 7261A   Description / Specification:    
FLUKE 7261A Universal Timer/Counter

The Fluke Model 7261A is a bench-type, portable Universal Timer/Counter. A self check mode of operation is provided to verify overall instrument performance. The instrument can make four types of measurements: frequency, period of an input frequency, time interval between any two events with averaging functions, ratio measurements of one frequency to another, and totalized count measurements. Both Channel A and B have an input impedance of 1 MOhm. Both Channels have trigger status lights, ± slope selection, 3 position attenuator switches, AC/DC coupling select controls, 100 kHz low pass filter select switches, analog trigger level outputs and the capability of bein gelectrically connected together. A marker output is available when either the TI A-B or the TIA A-B function is selected. The optional Channel C has an input impedance of 50 Ohms and is ac-coupled. This channel is used for frequency measurements only and has no Front Panel controls.



 

Standard Calibration $205.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 7261A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE 7261A CALIBRATION and/or FLUKE 7261A Universal Timer/Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: