FLUKE 79 III CALIBRATION and FLUKE 79 III REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 79 III Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 79 III (79-III)   Description / Specification:    
FLUKE 79 III Digital Multimeter

The Fluke 79 III Digital Multimeter has all ranges protected against overloads: voltages to 1000V dc, 1000V ac; resistance to 1000 V. All current inputs are protected with high energy fuses - including the 10 amp range. Specifications. DC Voltage Ranges: 40.00 mV, 400.0 mV, 4.000V, 40.00V, 400.0V, 1000V. DC Voltage Maximum Resolution: 0.01 mV. DC Voltage Accuracy: ± (0.3% reading + 1) @ 4.000 V. AC Voltage Ranges (45 Hz to 1 kHz): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V. AC Voltage Maximum Resolution: 0.1 mV. AC Voltage Accuracy: ± (1.9% reading + 4) @ 400 mV. DC Current Ranges: 4.000 mA, 40.00 mA, 4 A, 10.00 A. DC Current Maximum Resolution: 0.001 mA. DC Current Accuracy: ±(1.5% + 4) @ 4.000 mA. AC Current Ranges (45 Hz to 1 kHz): 4.000 mA, 40.00 mA, 4 A, 10.00 A. AC Current Maximum Resolution: 0.001 mA. AC Current Accuracy: ±(0.5% + 5) @ 4.000 mA. Resistance Ranges: 400.0, 4.000 k, 40.00 k, 400.0 k, 4.000 M, 40.00 M ohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: ± (0.4% reading + 2 digits) @ 400 ohm. Frequency Counter: 1.0 Hz to 20 kHz. Diode Range: 2.450 V. Display Digital: 4000 counts, updates 4/sec. Display Analog: 63 segments, updates 40/sec. Display Frequency: 9,999 counts. Display Capacitance: 9,999 counts. Response Time of Digital Display: VAC <1.5 s (for upscale only), VDC <1 s, ohms <1 s to 40 kohms, <2 s to 4 Mohms, <10 s to 40 Mohms.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 79 III. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 79 III CALIBRATION and/or FLUKE 79 III Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: