FLUKE 8012A REPAIR and FLUKE 8012A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE 8012A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 8012A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 8012A   Description / Specification:    
FLUKE 8012A 3 1/2 Digit Digital Multimeter

The Fluke 8012A is a 3 1/2 digit portable/bench DMM, that offers exceptional performance and features. Measurement functions include: dc volts, true-rms ac volts, dc amps, true-rms ac amps, ohms, conductance, and diode test. The 8012A has two additional ranges of low resistance - 2 ohms and 20 ohms. Along with the conductance function, that gives you a resistance range of 0.001 ohms to 10,000 M-ohms. A rechargeable-battery version is available as Model 8012A-01. The 8012A operates on ac line power only. A Fluke-manufactured true-rms converter assures accurate measurements of non-sinusoidal voltage or current waveforms such as squarewaves (crest factor of 1 to 1). This custom hybrid provides low noise and a wide bandwidth. Accuracy is specified to 50 kHz, but the typical -3 dB bandwidth is 200 kHz. When measuring resistance or conductance, up to 500 volts may be applied with no instrument damage. Voltage inputs can handle 1000V dc or peak ac and transients up to 6 kV. DC Voltage Ranges: ±200 mV, ±2V, ±20V, ±200V, ±1000V. DC Voltage Resolution: 100 uV on lowest range 1V on 1000V range. DC Voltage Accuracy: (±0.1 % of reading + 1 digit) on all ranges. AC Voltage Ranges: 200 mV, 2V, 20V, 200V, 750V. AC Voltage Resolution: 100 uV on lowest range 1V on 750V range. Useful Frequency Range: Typically ±3 dB at 200 kHz. Crest Factor: Waveforms with peak/rms ratio of 1:1 to 3:1. Resistance Ranges: 2, 20, 200, 2k, 20k, 200k, 2M, 20M ohms. Resistance Resolution: 1 m-ohm on lowest range 10 kohm on 20 Mohm range. Diode Test: The three diode test ranges are marked with a diode symbol and have enough open circuit voltage to turn on silicon junctions allowing a diode test. Open Circuit Voltage: < 3.5V on all ranges except <16V on 2 ohm and 20 ohm ranges. DC Current Ranges: 200 uA, 2 mA, 20 mA, 200 mA, 2000 mA. DC Current Resolution: 0.1 uA on lowest range 1 mA on 2000 mA range. AC Current Ranges: 200 uA, 2 mA, 20 mA, 200 mA, 2000 mA. Display: 3 1/2 digit (2000 counts), LCD, autozero, autopolarity.



 

Standard Calibration $60.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 8012A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 8012A REPAIR and/or FLUKE 8012A 3 1/2 Digit Digital Multimeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: