FLUKE 8062A CALIBRATION and FLUKE 8062A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 8062A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 8062A   Description / Specification:    
FLUKE 8062A 4 1/2 Digit TRMS Digital Multimeter

The Fluke 8062A 4 1/2-digit DMM offers more measurement capabilities than many bench/portable models. Well suited for engineers and technicians working in audio, video, telecommunications, or computer technology, both meters combine precision and accuracy with a wealth of features to fit nearly every application. True-rms ac voltage and current measurement. Fast audible-visual continuity tests. Relative Reference (offset). When measuring ohms with the 8062A the relative reference function displays only the difference between a stored reference value and a measured value, even if the range was changed between readings. Relative mode works in all functions and ranges. Specifications. VDC Range: 200 mV - 1000 V. VDC Best Accuracy: ±(0.05% + 2). VDC Resolution: 10 uV. VAC (True-RMS, AC Coupled) Range: 200 mV - 1000 V. VAC Best Accuracy: ±(0.5% + 10). VDC Resolution: 10 uV. ADC Range: 200 uA - 2000 mA. ADC Best Accuracy: ±(0.3% + 2). ADC Resolution: 0.01 uA. AAC (True-RMS) Range: 200 uA - 2000 mA. AAC Best Accuracy: ±(0.75% + 10). AAC Resolution: 0.01 uA. Resistance Range: 200 ohm - 300 M-ohm. Resistance Best Accuracy: ±(0.1% + 2). Resistance Resolution: 0.01 ohm.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 8062A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE 8062A CALIBRATION and/or FLUKE 8062A 4 1/2 Digit TRMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: