FLUKE DSP-4000 CALIBRATION and FLUKE DSP-4000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DSP-4000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DSP-4000 (DSP4000)   Description / Specification:    
FLUKE DSP-4000 LAN CableAnalyzer

The Fluke DSP-4000 LAN CableAnalyzer is a hand-held instruments used to certify, test, and troubleshoot coaxial and twisted pair cable in local area network (LAN) installations. The test tool combines test pulses with digital signal processing to provide fast, accurate results and advanced testing capabilities up to 350 MHz. It certifies LAN basic link and channel configurations to IEEE, ANSI, TIA, and ISO/IEC standards. The DSP-4000 stores at least 500 text-only test reports in nonvolatile memory. It produces plots of NEXT, ELFEXT, PSNEXT, PSELFEXT, attenuation, ACR, PSACR, and RL. Shows NEXT, ELFEXT, PSNEXT, PSELFEXT, attenuation, ACR, and PSACR results up to 350 MHz. Gives remote results for NEXT, PSNEXT, ACR, and RL. Specifications. Range Twisted Pair Cable: 0 ft to 328 ft, 328 ft to 2500 ft. Resolution Twisted Pair Cable: 1 ft or 0.1 m. Accuracy Twisted Pair Cable: ± (1 ft (0.3 m) + 2 % of reading) (0 ft to 328 ft), ± (1 ft (0.3 m) + 4 % of reading) (328 ft to 2500 ft). Range Coaxial Cable: 0 ft to 328 ft, 328 ft to 4000 ft. Resolution Coaxial Cable: 1 ft or 0.1 m. Accuracy Coaxial Cable: ± (1 ft (0.3 m) + 2 % of reading) (0 ft to 328 ft), ± (1 ft (0.3 m) + 4 % of reading) (328 ft to 4000 ft). Display: Graphic bit-mapped LCD with backlight and adjustable contrast.



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE DSP-4000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your FLUKE DSP-4000 CALIBRATION and/or FLUKE DSP-4000 LAN CableAnalyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: