FLUKE DSP-4300 REPAIR and FLUKE DSP-4300 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE DSP-4300. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DSP-4300 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DSP-4300 (DSP4300)   Description / Specification:    
FLUKE DSP-4300 LAN CableAnalyzer

The Fluke DSP-4300 LAN CableAnalyzer gives you a set of universal, compact modules that support many manufacturers’ cabling systems. Simply exchange the Personality Module (PM01 or PM02) at the end of the adapter for an easy, cost-effective solution with Cat 6 interoperability. Automatically diagnoses cabling faults and shows exact locations in feet or meters. Expanded 16 MB on-board memory saves up to a full day’s worth of testing (300 tests) if you forget your multimedia card, or fill up the card. Specifications. Range Twisted Pair Cable: 0 ft to 328 ft, 328 ft to 2500 ft. Resolution Twisted Pair Cable: 1 ft or 0.1 m. Accuracy Twisted Pair Cable: ± (1 ft (0.3 m) + 2 % of reading) (0 ft to 328 ft), ± (1 ft (0.3 m) + 4 % of reading) (328 ft to 2500 ft). Range Coaxial Cable: 0 ft to 328 ft, 328 ft to 4000 ft. Resolution Coaxial Cable: 1 ft or 0.1 m. Accuracy Coaxial Cable: ± (1 ft (0.3 m) + 2 % of reading) (0 ft to 328 ft), ± (1 ft (0.3 m) + 4 % of reading) (328 ft to 4000 ft). Propagation Delay Range Twisted Pair Cable: 0 ns to 500 ns, 500 ns to 3800 ns. Resolution Twisted Pair Cable: 1 ns. Accuracy Twisted Pair Cable: ± (5 ns + 2 % of reading) (0 ns to 500 ns), ± (5 ns + 4 % of reading) (500 ns to 3800 ns). Propagation Delay Range Coaxial Cable: 0 ns to 500 ns, 500 ns to 6000 ns. Resolution Twisted Pair Cable: 1 ns. Accuracy Twisted Pair Cable: ± (5 ns + 2 % of reading) (0 ns to 500 ns), ± (5 ns + 4 % of reading) (500 ns to 6000 ns). Delay Skew Range: 0 ns to 100 ns. Resolution: 1 ns. Accuracy: ± 10 ns. DC Loop Resistance Test: 0 to 400 ohms. Resolution: 0.1 ohm. Accuracy: ± (2 ohms + 2 % of reading).



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE DSP-4300. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE DSP-4300 REPAIR and/or FLUKE DSP-4300 LAN CableAnalyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: