FLUKE DTX-1200 REPAIR and FLUKE DTX-1200 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE DTX-1200. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DTX-1200 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DTX-1200 (DTX1200)   Description / Specification:   Spec Sheet 
FLUKE DTX-1200 CableAnalyzer

The Fluke DTX-1200 CableAnalyzer is a testing platform that reduces total time to certify by improving every aspect of the testing process. It starts with 9-second Cat 6 Autotest. That means you can meet TIA-568-C and ISO 11801:2002 certification requirements and receive structured cabling warranties faster than ever before. With all this speed also comes the highest accuracy as the DTX is the only tester to use a standards-compliant, electrically-centered permanent link test adapter. The AC Wiremap feature validates for Power over Ethernet services in accordance with TIA/EIA standards, even if a Midspan power supply is used. With over 50,000 units in use today, the DTX CableAnalyzer Series, is clearly the industry's choice as the most trusted cable certifier. Specifications. Cable Types: Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling. Standard Link Interface Adapters: Cat 6A/Class EA permanent link adapters. Test Standards: TIA Category 3, 5e, 6 & 6A per ANSI/TIA-568-C.2; TIA Category 5 (1000BASE-T) per TIA TSB-95; TIA Category 6 per TIA/EIA-568B.2-1; ISO/IEC 11801 Class C, D, and E, EA & F; EN 50173 Class C, D, E, EA & F; ANSI TP-PMD; IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T; IEEE 802.3an 10GBASE-T. Cable Tone Generator: Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz. Display: 3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE DTX-1200. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your FLUKE DTX-1200 REPAIR and/or FLUKE DTX-1200 CableAnalyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: