FLUKE DTX-1200 REPAIR and FLUKE DTX-1200 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE DTX-1200. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DTX-1200 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DTX-1200 (DTX1200)   Description / Specification:   Spec Sheet 
FLUKE DTX-1200 CableAnalyzer

The Fluke DTX-1200 CableAnalyzer is a testing platform that reduces total time to certify by improving every aspect of the testing process. It starts with 9-second Cat 6 Autotest. That means you can meet TIA-568-C and ISO 11801:2002 certification requirements and receive structured cabling warranties faster than ever before. With all this speed also comes the highest accuracy as the DTX is the only tester to use a standards-compliant, electrically-centered permanent link test adapter. The AC Wiremap feature validates for Power over Ethernet services in accordance with TIA/EIA standards, even if a Midspan power supply is used. With over 50,000 units in use today, the DTX CableAnalyzer Series, is clearly the industry's choice as the most trusted cable certifier. Specifications. Cable Types: Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling. Standard Link Interface Adapters: Cat 6A/Class EA permanent link adapters. Test Standards: TIA Category 3, 5e, 6 & 6A per ANSI/TIA-568-C.2; TIA Category 5 (1000BASE-T) per TIA TSB-95; TIA Category 6 per TIA/EIA-568B.2-1; ISO/IEC 11801 Class C, D, and E, EA & F; EN 50173 Class C, D, E, EA & F; ANSI TP-PMD; IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T; IEEE 802.3an 10GBASE-T. Cable Tone Generator: Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz. Display: 3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE DTX-1200. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your FLUKE DTX-1200 REPAIR and/or FLUKE DTX-1200 CableAnalyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: