Used AGILENT 86120B Buy / Purchase at the right Price.

Custom-Cal has a used AGILENT 86120B Optical Multi-Wavelength Meter in stock and ready for purchase at a fair price. All units sold by Custom-Cal are provided with an applicable NIST traceable calibration/performance verification and a 90 day warranty (unless otherwise noted). With this added service, you can be confident that you are buying a fully functional unit that meets OEM specifications.

We are always willing to work with the customer on price. If you would like to buy a used AGILENT 86120B but, don't see the price you want, please name your price below and we will try to find one for you to purchase.
AGILENT 86120B Optical Multi-Wavelength Meter


General description of the used AGILENT 86120B for sale.
The Agilent 86120B Multi-Wavelength Meter measures the wavelength and optical power of laser light in the 700- 1650 nm wavelength range. Because the Agilent 86120B simultaneously measures multiple laser lines, you can characterize wavelength-division-multiplexed (WDM) systems and the multiple lines of Fabry-Perot lasers.. Parameters: Wavelength Specifications; Range: 700 to 1650. Absolute accuracy (lines separated by >=30 GHz): ±3 ppm (±0.005 nm at 1550 nm and ±0.004 nm at 1310 nm). Differential accuracy (characteristic): ±2 ppm. Minimum resolvable separation (characteristic): 20 GHz (0.16 nm at 1550 nm, 0.11 nm at 1300 nm). Display resolution: 0.001 nm, normal update mode. Amplitude Specifications; Calibration accuracy at calibration wavelengths ±30 nm: ±0.5 dB (at 1310 and 1550 nm), 780 nm (characteristic). Flatness, ±30 nm from any wavelength: 1200 to 1600 nm (characteristic) ±0.2 dB, 700 to 1650 nm (characteristic) ±0.5 dB. Linearity, 1200 nm to 1600 nm, lines above -30 dBm: ±0.3 dB. Polarization dependence: 1200 to 1600 nm ±0.5 dB, 700 to 1650 nm (characteristic) ±1.0 dB. Display resolution: 0.01 dB. Sensitivity Specifications; Single line input: 700 to 900 nm: -20 dBm, 900 to 1200 nm: -25 dBm, 1200 to 1600 nm: -40 dBm, 1600 to 1650 nm: -30 dBm. Multiple lines input (characteristic): 700 to 1650 nm, 30 dB below total input power, but not less than single line input sensitivity. Selectivity Specifications; Two lines input separated by >= 100 GHz (characteristic): 25 dB. Two lines input separated by >= 30 GHz (characteristic): 10 dB. Input Power: Maximum displayed level (sum of all lines) +10 dBm, Maximum safe input level (sum of all lines) +18 dBm. Maximum Number of Laser Lines Input 100. Input Return Loss; With straight contactconnectors: 35 dB, With angled contact connectors (Option 022): 50 dB. Measurement Cycle Time; Normal update mode (characteristic): 1.0 s (1 measurement-per-second). Signal-to-Noise Ratio (characteristic); channel spacing >= 200 GHz: >35 dB (0.1 nm noise bandwidth), lines above -25 dB

       Stock Photo     

Unfortunately, the instrument you wanted to buy has recently been sold.
But, if you fill out the form below, we will get back to you with availability and price.
Please check the similar instruments available for purchase below.



Similar Instruments Available for Purchase. Please follow links for more information and price.

 ManufacturermodelInstrument TypeOEM NameStarting Price
Price and InfoAGILENT86120CWavelength MeterOptical Multi-Wavelength MeterBuy it Now Price $8,950.00
Price and InfoEXFOIQ-5320Wavelength Meter1450 to 1650 nm Multi-Wavelength Meter ModuleBuy it Now Price $2,950.00
Price and InfoILX LIGHTWAVEOMM-6810BWavelength MeterOptical Power and Wavelength MeterBuy it Now Price $2,400.00

Contact us to buy used AGILENT 86120B at the Purchase Price you want.

Calibration Type (Select one):
 (*) Required Fields    For formal quote please fill in all fields.
From (Email):*
Contact Name:*
Company:
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*


Comment: