Keysight (Agilent) 86100D REPAIR and Keysight (Agilent) 86100D CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86100D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86100D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Communication Analyzer?
Shop for Comparable Products on our
 used Communication Analyzer page or new Communication Analyzer page

 
   Keysight (Agilent) 86100D   Description / Specification:   Spec Sheet 
Keysight (Agilent) 86100D Infinium DCA-X Wide-Bandwidth Oscilloscope

The Keysight 86100D DCA-X performs precision measurements on high-speed digital designs from 50Mb/s to more than 80 Gb/s on up to 16 channels simultaneously. Applications include:
Optical - Transceiver Design and Manufacturing.
Electrical - ASIC/FPGA/IC Design and characterization.
TDR/TDT/S-Parameter - Serial Bus Designs, Cables, and PCB characterization.
The DCA-X provides powerful analysis capability that is enabled through licensed software options.
Mainframe specifications.

Horizontal system (time base).
Scale factor (full scale is ten divisions): 2 ps/div (with 86107A or 86100D-PTB: 500 fs/div) min, 1 ps/div max.
Delays: 24 ns min, 1000 screen diameters or 10 s whichever is smaller max.
Time interval accuracy: 1 ps + 1.0% of delta time reading or 8 ps, whichever is smaller.
Jitter mode operation: Time interval accuracy - jitter mode operation 1 ps.
Time interval resolution: ≤ (screen diameter)/(record length) or 62.5 fs, whichever is larger.
Display units: Bits or time (TDR mode-meters).

Vertical system (channels).
Number of channels: 16 (simultaneous acquisition).
Vertical resolution 54xxx, 83xxx, 86xxx: 14 bit A/D converter (16 or more bits with averaging).
Record length Legacy UI: 16 to 16K samples, FlexDCA without pattern lock: 16 to 64K samples, FlexDCA with pattern lock: 16 up to 32M samples.

Trigger modes.
Internal trigger: Free run.
External direct trigger: DC to 100 MHz (Limited bandwidth), DC to 3.2 GHz (Full bandwidth).

Jitter.
Characteristic: < 1.0 ps RMS + 5*10E-5 of delay setting.
Maximum: 1.5 ps RMS + 5*10E-5 of delay setting.

Trigger.
Sensitivity: 200 mVpp (sinusoidal input or 200 ps minimum pulse width).
200 mVpp sinusoidal input: 50 MHz to 13 GHz, (to 32 GHz with option PTB)
Trigger configuration Trigger level adjustment: -1 V to + 1 V.
Edge select: Positive or negative.
Hysteresis: Normal or High sensitivity.

Options.
-STR; Standard trigger.
-ETR; Enhanced trigger.
-PTB; Precision timebase integrated in the mainframe.
-GPI; GPIB card interface installed (default).
-GPN; No GPIB card interface.
-090; Removable hard drive.
-092; Internal hard drive (default).
-061; MATLAB - Basic Oscilloscope Package.
-062; MATLAB - Standard Oscilloscope Package.
-200; Enhanced Jitter analysis software.
-201; Advanced waveform analysis software.
-202; Enhanced impedance and S-parameter software.
-300; Amplitude analysis/RIN/Q-factor.



 

Standard Calibration $515.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86100D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Decibel (dB)
A unit of measurement of optical power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

PDH
Plesiochronous Digital Hierarchy (PDH) is a transmission system for voice communication using plesiochronous synchronisation. The transmitter adds dummy information bits to allow multiple channels to be bit interleaved. The receiver discards these bits once the signals have been demultiplexed. PDH combines multiple 2 Mb/s (E1) channels in Europe and 1.544 Mb/s (DS1) channels in the US and Japan.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).


Please contact us for your Keysight (Agilent) 86100D REPAIR and/or Keysight (Agilent) 86100D Infinium DCA-X Wide-Bandwidth Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: